GAS TURBINE

Current Location:Home > PRODUCTS > GAS TURBINE

GAS TURBINE

Product Name: GAS TURBINE
Product NO: GAS TURBINE
Power: 5.25MW~47MW
Rated Voltages: 6.3 kV(or 10.5kV)
Number of poles:
Frequency: 50Hz/60Hz
Peotection class:
Frame Size:

Detail

 Brief Introduction

 The gas turbine is the prime mover in the gas turbine electricity generator setit transforms the heat energy in the fuel into mechanism energy, then the generator transforms the mechanism energy into electricity energy , at the same time the exhaust gas comes into recovery boiler across vent-pipe, and produce steam.

l  5.25MW ~47MW Power generation of 5.25 MW~47MW

l  Accepted by the Oil and Gas industry

l  80% Proven cogeneration efficiencies greater than 80%

l  Used in 114 cogeneration applications worldwide

l  225 total sales worldwide

l  111 simple cycle applications worldwide

 

 

 

Ordering data

 1.PERFORMANCE PARAMETER of  GT 100

the principal technical data of SGT100

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT100
  • output power 5250kw
  • fuel: Natural gas
  • electrical efficiency: 30.5%
  • heat consumption 11815kj/kwh(11199but/kwh)
  • turbine speed 17384rpm
  • pressure ratio 14.6:1
  • exhaust temperature 530
  • exhaust flow 20.8kg/s(45.8lb/s)
  • NOx emissions: ≤25ppmv   

 

2.PERFORMANCE PARAMETER of  GT 200

the principal technical data of SGT200

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ
  • GT model: SGT200
  • output power 6750kw
  • fuelNatural gas
  • electrical efficiency: 31.7%
  • heat consumption 11420kj/kwh
  • turbine speed 11085rpm
  • pressure ratio 12:1
  • exhaust temperature 566
  • exhaust flow 29.3kg/s
  • Nitrogen oxide emissions: ≤25ppmv
  • lengthmm): 10900mm
  • Widthmm): 2400mm
  • Heightmm): 3300mm
  •  Unit Weightkg): 56250kg 

   The parameters of compressor related

 

  • Type 4MW-90/22
  • Exhaust volume 90 Nm³/min
  • Inlet pressure): Atmospheric pressure
  • Exhaust pressure 2.2MPa
  • Inlet temperature: ≤35
  • Exhaust temperatureafter cooling 50
  • Shaft power: ≤782kw
  • Cooling water): <90t/h(With cooler)
  • Motor power 900KW
  • Motor voltage 10.5kV
  • Motor frequency 50HZ
  • Compressor size 6200mm×7100mm×2500mm

  

 

 3.PERFORMANCE PARAMETER of  GT 300

the principal technical data of SGT300

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT300
  • output power 7900kw
  • fuel: Natural gas
  • electrical efficiency: 31.2%
  • heat consumption 11532kj/kwh(10930but/kwh)
  • turbine speed 14010rpm
  • pressure ratio 13.7:1
  • exhaust temperature 537
  • exhaust flow 29.8kg/s(65,6lb/s)
  • NOx emissions: ≤15ppmv   

 

4.PERFORMANCE PARAMETER of  GT 400

the principal technical data of SGT400

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT400
  • output power12900kw
  • fuel: Natural gas
  • electrical efficiency: 34.8%
  • heat consumption 10355kj/kwh(9815but/kwh)
  • turbine speed 9500rpm
  • pressure ratio 16.8:1
  • exhaust temperature 555
  • exhaust flow 39.4kg/s(86.8lb/s)
  • NOx emissions: ≤15ppmv   

 

5.PERFORMANCE PARAMETER of  GT 500

the principal technical data of SGT500

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT500
  • output power18600kw
  • fuel: Natural gas
  • electrical efficiency: 32.2%
  • heat consumption 11180kj/kwh(10597but/kwh)
  • turbine speed3600rpm
  • pressure ratio 12:1
  • exhaust temperature 375
  • exhaust flow 92.3kg/s(203.7lb/s)
  • NOx emissions: ≤ 42ppmv   

 

6.PERFORMANCE PARAMETER of  GT 600

the principal technical data of SGT600

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT600
  • output power24770kw
  • fuel: Natural gas
  • electrical efficiency: 34.2%
  • heat consumption 10533kj/kwh(9983but/kwh)
  • turbine speed7700rpm
  • pressure ratio 14:1
  • exhaust temperature 543
  • exhaust flow 80.4kg/s(177.3 lb/s)
  • NOx emissions: ≤ 25ppmv   

 

7.PERFORMANCE PARAMETER of  GT 700

the principal technical data of SGT700

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT700
  • output power31210kw
  • fuel: Natural gas
  • electrical efficiency: 36.4%
  • heat consumption 9822 kj/kwh(9367 but/kwh)
  • turbine speed6500rpm
  • pressure ratio 18.6:1
  • exhaust temperature 528
  • exhaust flow 94 kg/s(208 lb/s)
  • NOx emissions: ≤ 15ppmv   

 

8.PERFORMANCE PARAMETER of  GT 800

the principal technical data of SGT800

  • rated output voltage: 6.3 kVor 10.5kV
  • frequency: 50HZ/60Hz
  • GT model: SGT800
  • output power47000kw
  • fuel: Natural gas
  • electrical efficiency: 37.5%
  • heat consumption 9579 kj/kwh(9096 but/kwh)
  • turbine speed6008rpm
  • pressure ratio 19:1
  • exhaust temperature 544
  • exhaust flow 131.5 kg/s(289.9 lb/s)
  • NOx emissions: ≤ 15ppmv   

 

PERFORMANCE CURVES

QDR70 performance at ISO Condition

 EXHAUST GAS

CONTENT OF SUPPLY

 

No.

description

quantity

remark

1

QDR70 unit

1 units

(main part)

 

2

core engine

Matching standardly

 

3

Generator

Matching standardly

 

4

retarder

Matching standardly

 

5

coupler

Matching standardly

 

6

underbase and box

Matching standardly

 

7

Air inlet filtrate

silencer

Matching standardly

 

8

Exhaust connection

Matching standardly

 

9

DLE Instrument air system

Matching standardly

 

10

Gas turbine seal and pollution

Matching standardly

 

11

Box body electrical assembly

Matching standardly

 

12

High pressure system

Matching standardly

 

13

Dc screen

Matching standardly

 

14

base

Matching standardly

 

15

Unit box body

Matching standardly

 

16

Control system

Matching standardly

 

17

Motor control center

Matching standardly

 

18

Start system

Matching standardly

 

19

Lubricating oil system

Matching standardly

 

20

Lubricating oil cooler system

Matching standardly

 

21

Gas fuel system

Matching standardly

 

22

Fire and lighting system 

Matching standardly

 

23

Inter and exhaust system

Matching standardly

 

24

other apparatuses

Matching standardly

 

25

compressor

1 units

The cost will be calculated separately if it is necessary.

26

Compressor unit

Matching standardly

 

27

Water resistance soft starter

Matching standardly

 

28

Cyclone separator

Matching standardly

 

29

filter

Matching standardly

 

30

cooler

Matching standardly

 

31

gasholder

Matching standardly

 

32

Thermometer table regulating voltage stabilizer

Matching standardly

 

33

Thermometer table

Matching standardly

 

34

Pressure instrument

Matching standardly

 

35

Control cabinet

Matching standardly

 

36

other apparatuses

Matching standardly

 

37

accessory system

1 units

The cost will be calculated separately  if it is necessary.

38

Circulating water cooling system

Matching standardly

 

39

Water Treatment System

Matching standardly

 

40

Instrument air system

Matching standardly

 

41

drainage

Matching standardly

 

42

other apparatuses

Matching standardly

 

43

Cost of design

Done standardly

 

 Note

1. The above quotation is based on Chinese Industrial Standards (CIS), the price will fluctuate according to different Standards (local Standard or International Standard ).

2.The quoted price for above compressor is based on that the fuel inlet pressure is normal atmosphere (An). the price will fluctuate according to actual inlet pressure.

3. All above price is EXWINCOTERMS 2000, excluding transportation.

 TECHNICAL SERVICE (an extra need to charge)

*  The supplier will supply the Instructional Manual for the Power station and maintenance manuals for various equipments.

*  If required by the purchaser, the supplier can offer the service of operation of the equipment of the power station.

*  The customer may get help in training the personals in proper operation and maintenance procedures.

*  To provide spares for the usage of one or two years (to be charged )

*  The warranty period for the equipment of power station is one year from delivery.

*  The supply of spare parts is guaranteed.

 

 The delivery schedule

Delivery schedule12months

Installation cycle60days

Test cycle30days 

 

技术支持
点击这里给我发消息
产品咨询
点击这里给我发消息
销售一号
点击这里给我发消息
销售2号
点击这里给我发消息